久久久精品免费_成人综合网站_国产ⅩXXX推油按摩BBBB_7777精品久久久大香线蕉

歡迎來到北京豫維科技有限公司網站!

熱門關鍵詞:蘇瑪罐,原子吸收分光光度計,環境監測產品,液相色譜,色譜柱。

產品中心您現在的位置:首頁 > 產品展示 > 液相色譜柱 > 離子色譜柱 > Dionex IonPac AS21 陰離子交換柱 063009

Dionex IonPac AS21 陰離子交換柱 063009

更新時間:2019-11-20

簡要描述:

Dionex IonPac AS21 陰離子交換柱 063009
柱的容量和選擇性使快速分析高氯酸鹽在低μg/L濃度。

  免費咨詢:010-61755520

  發郵件給我們:yuweichina86@163.com

Dionex IonPac AS21 陰離子交換柱 063009

當你需要快速分離飲用水中高氯酸鹽與質譜檢測之前,Thermo Scientific? Dionex IonPac AS21氫氧化物選擇性陰離子交換柱柱的選擇。本專欄是具體列出在美國環保局的方法331。柱的容量和選擇性使快速分析高氯酸鹽在低μg/L濃度。此外,該2x250毫米列格式設計和LC-MS和LC-MS/MS兼容性方便使用如jia胺揮發性流動相優化

 

Dionex IonPac AS21 陰離子交換柱 063009

訂貨信息:

Dionex IonPac AS21 陰離子交換柱

分析柱
IonPac AS21 Analytical Column (2 x 250 mm)63009
保護柱
IonPac AG21 Guard Column (2 x 50 mm)63071

 

 

 

For Fast Analysis of Trace Perchlorate in Drinking Water Prior to Detection with MS/MS

The AS21 hydroxide-selective anion-exchange column is specifically designed for determination of trace perchlorate in drinking water prior to MS/MS detection. The capacity and selectivity enable fast analysis of perchlorate at low μg/L concentrations. The AS21 is the specified column in US EPA Method 331.0.

  • Fast separation of perchlorate prior to MS/MS detection

  • Optimized for methylamine or hydroxide mobile phases

  • Specified column for US EPA Method 331.0

  • Optimum capacity: 45 μeq per column (2 × 250 mm)

  • Operates at ambient or elevated temperatures

  • Compatible with organic solvents

The AS21 2 × 250 mm column format was specifically developed for MS/MS compatibility to allow use of volatile mobile phases such as methylamine.

 

 

IonPac AS21 Anion-Exchange Column Specifications
Dimensions:IonPac AS21 Analytical Column:
2 × 250 mm
IonPac AG21 Guard Column:
2 × 50 mm
Maximum Operating Pressure:3000 psi
Mobile Phase Compatibility:pH 0–14; 0–100% HPLC solvents
Substrate Characteristics:Bead Diameter and Pore Size:
7 μm (2 × 250 mm); super macroporous resin (2000 ?)
11 μm (2 × 50 mm); microporous resin (<1 ?)
Crosslinking (%DVB): 55%
Ion Exchange Group:Functional Group: Alkanol quaternary ammonium ion
Functional Group Characteristics:Ultralow Hydrophobicity
Capacity:45 μeq (2 × 250-mm analytical column)
1.5 μeq* (2 × 50-mm guard column)
*Guards are packed with a low-capacity microporous resin.
Column Construction:PEEK with 10–32 threaded ferrule style end fittings.